Maintenance Object Repair Procedures 
Page 10-298CO-DS1 (DS1 CO Trunk) 
10
1018 ABORT Thest is disabled via tranlsation. You may want to determine why the test 
has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Group’ form is set 
to ’n’. To enable the test, issue the change trunk-group x command (x 
equals the number of the trunk group to be tested). Then, change the 
entry in the ’Maintenance Test’ field on the form to ’y’.
2. Repeat the test.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in the Hardware Error Log. If present, refer to 
DS1-BD (DS1 Trunk Circuit Pack) Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
1040 ABORT The test was aborted because this port may be an access endpoint.
1. Verify that this port is an access endpoint by issuing the display port 
command.
2. If the port has been administered as an access endpoint, then this is a 
normal abort.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2012 ABORT The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals for a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
Table 10-98. TEST #314 DS1CO Dial Tone Seizure Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page