User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-185BRI-SET, ASAI-ADJ, BRI-DAT 
10
adjunct. If these attempts fail, the problem should be escalated because 
re-engineering of the traffic on the PKT-CTRL, signaling link, or adjunct 
may be necessary.
i. This error indicates a problem with Layer 2 over the D-channel between 
the switch and the endpoint. When this error occurs, an alarm is raised 
against the station or adjunct. Execute the test station extension short 
command and pay particular attention to the results of the BRI XID Test 
(#628). If this test fails, follow the repair procedure for Test #628.
j. This error indicates a problem with the B-channel connection between the 
switch and the endpoint. When this error occurs, a warning alarm is raised 
against the endpoint. Execute the test station extension l command, and 
pay particular attention to the results of the BRI Remote Loop Back Test 
(#627). If this test fails, follow the repair procedure for Test #627.
k. This error occurs whenever the point-to-point signaling link to the endpoint 
goes down (except when it goes down because either the PKT-CTRL or 
the PKT-BUS has failed or has been busied out by system technician). 
When this error occurs, an alarm is raised against the endpoint or adjunct. 
Execute the test station extension short command and pay particular 
attention to the results of the Signaling Link Status Test (#626). If this test 
fails, follow the repair procedure for Test #626. The alarm is retired when 
the signaling link is reestablished to the endpoint or adjunct.
l. Certain ASAI protocol-specific cause codes are logged by switch 
software. The cause code can be determined from the following formula:
If the error type is greater than 3712, then the ASAI cause code is equal to 
the error type minus 3712. This code was sent to the adjunct by the 
switch.
If the error type is less than 3712, then the ASAI cause code is equal to the 
error type minus 3584. This code was sent to the switch by the adjunct.
A description of the various ASAI cause values is contained in the Table 
10-64. This table also contains recommended system technician actions 
associated with the cause value. Further information can also be found in 
the AT&T ASAI Specification (AT&T PUB 288-500-03). In addition, the Aux 
Data field of the Error Log entry contains additional diagnostic information.
Table 10-66. ASAI Cause Values
Code Explanation Recommendation
Service or Option 
Not Available
Continued on next page