Maintenance Object Repair Procedures 
Page 10-182BRI-SET, ASAI-ADJ, BRI-DAT 
10
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol; 
timers associated with certain Layer 3 messages have expired before a 
required response was received. In the following table, the aux data field 
indicates which timer has just expired. (For more information, refer to the 
AT&T ISDN-BRI Specification.)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the 
set options command.
3073(j) 0 BRI Remote 
Loop Back 
(#627)
WARNING OFF test station ext l 
r 2
test 
data-module 
ext l r 2
3329(k) Any Signaling Link 
Status (626)
WARNING MAJOR/ 
WARNING
2
OFF †
3584 0, 1 None
3585- 
3839(i)
0 None
3840- 
4095(m)(
n)
0 None
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
6 Second T308 (RELease timer)
10 T316 (RESTart timer)
Table 10-65. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error 
Type
Aux 
Data
Associated 
Test
Alarm 
Level 
BRI-PORT
Alarm Level 
ABRI-PORT 
ATT-PORT 
LGATE-PORT
 ATTE-PT
On/ 
Off 
Board
Test to Clear 
Value
Continued on next page