User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-167BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use the status station 
command for the station associated with this port and determine when the 
port is available for testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
1005 ABORT This test is not valid for this type of translation. Ports administered as 
“ASAI” or “ADJK” can not run this test, because the B channels associated 
with the port are not used by ASAI or AT&T Adjunct Links. This is a normal 
condition.
2000 ABORT Response to the test was not received from the BRI-LINE circuit pack 
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the 
other ports are not in use. Reset the circuit pack by issuing the 
busyout board PCSS and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-58. TEST #619 BRI Port Local TDM Loop Around — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page