User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Management Terminals 
Page 3-22System Login Procedure 
3
After the user enters the correct login name and password and the login is 
administered correctly, the system displays the command line interface.
To log into the system, do the following:
1. Turn on the administration terminal. Verify that the screen displays: 
login:
2. Enter your login name, then press 
Enter. Verify that the screen displays: 
password:
3. Enter your password, then press 
Enter.
For security reasons, the password is not displayed as you type it. The 
system verifies that a valid login and password name were entered. If an 
invalid login or password name was entered, the screen displays:
login incorrect:, and you must repeat the procedure.
If the system recognizes the login and password name, verify that the 
screen displays the software version.
4. For your terminal type, complete one of the following:
Terminal Type (Enter 513, 715, VT220, 4410, or 4425): [513]
a. If the terminal is a 513 BCT, press Enter. The 513 in brackets [513] is 
the system default terminal.
b. If the terminal is a 610 BCT or a 615 MT that has a 513 emulation 
cartridge, press 
Enter.
c. If the terminal is a 610 BCT or a 615 MT that does not have a 513 
emulation cartridge, enter 4410 and press 
Enter.
d. If the terminal is any other of the types listed, enter the terminal type 
and press 
Enter.
5. You can deactivate INADS alarm origination whenever you log in as craft. 
After you supply the terminal type information requested, the system 
displays the following if alarm origination is activated on the Maintenance 
System-Parameters screen:
NOTE:
Unless you are in a special situation, please reduce unnecessary 
trouble tickets by always answering “y” to the following prompt to 
suppress Alarm Origination.
Suppress Alarm Origination: [y] 
The default answer is yes. If you do NOT wish to suppress alarm 
origination, enter no. Any other entry defaults to yes. The test inads-link 
command works regardless of whether you have overridden INADS alarm 
origination.
6. Verify that the screen displays:
 enter command: