Page 8-365test memory 
8
test memory
This command performs hardware diagnostic tests on any or all memory circuit 
packs in the specified carrier. Both short and the long test are nondestructive 
when testing memory.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
 long 
clear
 option forces a clear of all alarms if no errors are encountered during testing. The 
short clear
 option only 
clears alarms pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test memory location
short
long
repeat 
number
clear
schedule
Physical location of the memory 
circuit pack: cabinet number 
(optional, but always 1 if entered) 
and carrier letter (either a or b for 
duplex, a for simplex)
Option for a brief series of 
nondestructive diagnostic tests.
Option for a longer, more 
comprehensive test series (all 
nondestructive for this command).
Number of times each test in the 
sequence is repeated (1-100)
This option causes the test 
sequence (short or long) to repeat 
until the alarm (if any) is cleared or 
a single test in the sequence fails.
1
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue and 
is executed at the specified time. 
The information displayed by the 
command is sent to the system 
printer instead of the screen.
2
Examples:
test memory
test memory a
test memory a schedule
test memory 1a2
test memory b1 sh
test memory b l r 25
test memory a l c