DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-334test data-module 
8
Defaults
The default cabinet is cabinet 1. The default carrier is carrier “a,” except for SPE 
duplex system PPNs. In this case the carrier has no default and either “a” or “b” 
must be entered. The default for the remaining parameter is a repeat of 1.
Output
The following example shows the output from the test customer-alarm 02a 
command.
Field Definitions
test data-module
This command performs hardware diagnostic tests on a data module or data 
channel. Test results are determined by the interface to the digital switch-data 
line port, digital line port, or network control data channel.
Port The port address (cabinet-carrier-slot)
Maintenance 
Name
The maintenance name (always CUST-ALM)
Alt. Name Not applicable
Test No. The test number (always 115)
Result Test result: Pass, Abort, or Fail
Error Code Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 test customer-alarm 02A
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 02A CUST-ALM 115 PASS
 Command Successfully Completed