Page 8-305status system 
8
BUS 
ALARMS-MAJOR
Whether Major alarms exist for packet bus components (y or n)
BUS 
ALARMS-MINOR
Whether Minor alarms exist for packet bus components (y or n)
BUS FAULTS Number of faulty bus leads (defined as shorted to another lead, 
stuck at some value, or an open lead: 0 - 24). This field may take on 
any integer between 0 and 24. This field displays blank if:
■ Maintenance/Test circuit pack not present
■ Packet Bus port of the Maintenance/Test circuit pack has been 
taken out-of-service
■ System does not have the Packet Bus feature
OPEN BUS 
LEADS
Number of open bus leads between the Maintenance/Test circuit 
pack and bus terminator (0 - 24). This could mean physical damage 
to the backplane or its connectors or a missing bus terminator. This 
field displays blank if:
■ Maintenance/Test circuit pack is not present
■ Packet Bus port of the Maintenance/Test circuit pack has been 
taken out-of-service
■ System does not have the Packet Bus feature.
EMERGENCY 
TRANSFER
Location of the Processor or EPN Maintenance circuit pack 
containing the Emergency Transfer Select Switch (1A and 1B for the 
PPN, and 2A or 3A for the EPNs)