User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-300status synchronization 
8
status synchronization
This command displays the location of the DS1 or tone-clock circuit pack that is 
used for an on-line synchronization reference. The synchronization subsystem 
provides error free digital communication between the switch and other PBXs, 
COs, or customer premise equipment. The subsystem is made up of: TDM bus 
clock, DS1 trunk board, maintenance and administration software resident in the 
SPE.
Service State In service/on-hook, in service/off-hook, out of service, or 
disconnected.
Maintenance 
Busy State
Whether maintenance is testing the object (yes or no)
SAC Activated Whether send all calls is activated (yes or no)
User Cntrl 
Restr
One or two of the following: none, total, stat-stat, outward 
or terminate.
Group Cntrl 
Restr
One or two of the following: none, total, stat-stat, outward 
or terminate.
AWU Call at Time that Automatic Wakeup Call is scheduled
User DND Status of the do not disturb feature.
Group DND Status of the group do not disturb feature.
Room Status Whether a room is occupied or not (non-guest room, vacant, or 
occupied).
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status 
synchronization
print
Report sent to printer
Examples:
status synchronization
status synchronization print
init
inads
craft
cust
browse
none none