User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-283status link 
8
Output
The following example is a display of the status journal-link wakeup-log 
command.
Field descriptions
status link
The status link command displays the operational status associated with a 
specified processor interface link.
Link State
If extensions are administered in the System Parameters 
Hospitality form, wakeup-logs or pms-log links are considered to 
be administered only.
Maintenance Busy
Is maintenance testing performing on the link?
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status link
link 
number
print
A link number (1-8) associated 
with a specific link.
Report sent to printer.
Examples:
status link 1
status link 8
status link 4 print
init
inads
craft
cust
rcust
bcms
browse
none none
 status journal-link wakeup-log
 JOURNAL LINK STATUS
 Link State: up
 Maintenance Busy? no