User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-156monitor health 
8
Output
The following example is a display of the monitor system health command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
monitor health init
inads
craft
cust
nms
browse
none If standby SPE 
Emergency Transfer 
Select Switches change 
and handshakes are 
down, the displayed 
Emerg Trans field is 
incorrect until 
handshake reintializes.
When the monitor health 
command terminates, 
users are logged off of 
the system.
Major
The number of logged major alarms (0 – 200).
Minor
The number of logged minor alarms (0 – 200).
Warning
Number of warnings logged in the alarm file (0 – 200).
Trunks
Number of busied out maintenance trunks.
Stations
Number of busied out maintenance stations.
status health
 ALARM SUMMARY CABINET STATUS
 Major: 0
 Minor: 9 Emerg Alarms
 Warning: 4 Cab Trans Mj Mn Wn PNC
 1 off 0| 7| 0 up
 BUSY-OUT SUMMARY 2 off 0| 0| 4 up
 Trunks: 0 3 n.a. 0| 2| 0 up
 Stations: 0 4 off 0| 0| 0 up/up
 Others: 0
 PROCESSOR OCCUPANCY STATUS
 Static: 3% SM: 6%
 CP: 10% Idle: 81%
 CRITICAL SYSTEM STATUS
 Active SPE: A/auto
 Duplicated? SPE:n
 SPE Power: commercial
 Time Source: external 9:33 TUE JAN 29 1991
 # Logins: 2 - Press CANCEL to quit -