User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-114list mst 
8
1. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list mst
from message 
number
count number
Message number to start the 
display; if the number is not in 
the buffer, then that is indicated 
on the display, and no additional 
messages are displayed. 
Omitting this qualifier causes 
messages to be displayed 
starting with the oldest FIFO and 
continuous messages.
Message count; can be used to 
limit the trace
init
inads
FIFO order See 
documen-
tation on the 
system 
printer 
feature.
continuous
Display updates as new 
messages enter the trace buffer 
(FIFO). This option is most useful 
in conjunction with "auto-page." 
The command terminates only 
when canceled by the user.
LIFO
Newest message displayed first.
FIFO
Messages displayed in the order 
received.
[ auto-page ]
The screen will automatically 
page when full. Used in 
combination with 
continuous
(above), provides a way to 
"watch" as messages arrive.
print
schedule
Report sent to printer.
Command is validated and then 
a scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue 
and is executed at the specified 
time. The information displayed 
by the command is sent to the 
system printer instead of the 
screen.
1
Examples:
list mst continuous
list mst continuous auto-page
list mst LIFO
list mst from 222 count 7