Maintenance Commands and Trouble-Clearing Aids 
Page 8-84display system-parameters maintenance 
8
Modem Connection
On page 3 of the example forms shown below, there are 11 fields that are hidden 
when the Modem Connection? field is set to internal. In this example the 
Modem Connection field is set to external and these additional 11 fields are 
visible.
The first 2 fields on page 3 help setup the data format for the serial data from the 
switch to the modem. The field names are Data Bits: and Parity?. There are 
only two valid combinations for these 2 fields:
■ Data Bits = 8, Parity = None
■ Data Bits = 7, Parity = (odd, even, mark, or space)
The remaining fields are listed below:
No. of Parties to Be 
Conferenced Enter Digit
32
43
54
65
76
SPE Optional 
Boards:
These fields indicate whether a Disk circuit pack is present in the 
system, and which Packet Interface slots are administered. If a 
Packet Interface circuit pack is physically present, the 
corresponding Packet Interface field is set to y when the system 
boots, and no change to that field is allowed. If the system is 
equipped with duplicated SPEs, a Packet Interface field is set to y 
when either SPE carrier contains a Packet Interface circuit pack in 
the corresponding position. If a Packet Interface circuit pack is not 
present, then the value for the Packet Interface field is read from 
translation data stored on disk or tape. If the field is set to n, a 
Packet Interface circuit pack may be administered by changing the 
corresponding Packet Interface field to y.
Modem Connection
Valid entries for this field are “internal” or “external”. The default is 
set to internal. (internal)
Modem Name
20-characters alpha-numeric field for a unique modem name