Page 8-79display system-parameters maintenance 
8
Alarm Origination to 
OSS Numbers
One of four options for alarm origination (neither):
■ If both, all Major and Minor alarms result in an automatic 
call to both OSS telephone numbers. Both OSS telephone 
numbers must be administered.
■ If first-only, all Major and Minor alarms result in an 
automatic call to the first OSS number only. The switch does 
not call the second OSS telephone number even if the 
number is administered. The first OSS telephone number 
must be administered
■ If neither, alarm origination does not take place. Warning 
alarms are not reported to either numbers.
■ If second-as-backup, all Major and Minor alarms result in 
an automatic call to the first OSS telephone number. If 
calling the first OSS telephone number fails four attempts, 
the switch starts to call the second OSS telephone number 
as a backup until calling the first OSS telephone number 
becomes successful. Both OSS telephone numbers must be 
administered.
Before Release 5, the name of this field is Alarm 
Origination Activated. If Alarm Origination is deactivated, 
both Cleared Alarm Notification and Restart Notification are 
disabled, even though they may still be activated in the 
administration.
Cleared Alarm 
Notification
Enables the switch to originate a call to the OSS and send an 
alarm resolution message whenever all previously-reported 
Major and Minor alarms are resolved. Alarm Origination must be 
activated in order for Cleared Alarm Notification to work. (no)
Restart Notification
Enables the switch to originate a call to the OSS and report any 
system restarts caused by problems with the switch.
Suspension Threshold
The threshold for suspending Cleared Alarm Notification (1-15). 
Some problems may cause alarms to be generated and then 
resolved repeatedly. To detect these problems (by not sending 
additional Cleared Alarm notifications to indicate a problem- 
free system), the switch suspends Cleared Alarm Notification 
when it has reported this administrable number of Cleared 
Alarm notifications in a 24-hour period. A suspended Cleared 
Alarm Notification is only enabled again with a successfully 
completed “logoff” command, a system reset, or when the 
threshold is changed. This field is irrelevant if Cleared Alarm 
Notification or Alarm Origination is disabled.
Test Remote Access 
Port
Specifies whether testing of the remote access port on the 
SYSAM circuit pack is enabled. This field should read yes 
whenever there is an INADS line connected to the switch and 
there is a maintenance contract in effect so that alarm 
origination capability is maintained.