User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-15busyout pri-endpoint 
8
Output
The following example is a display of the busyout port command.
Field descriptions
busyout pri-endpoint
This command places all PRI endpoint ports (B-channels) associated with the 
specified PRI endpoint in a maintenance busy (system technician busy) state. No 
periodic or scheduled tests are performed on the busied out PRI endpoint ports 
until they are released. When the PRI endpoint port is maintenance busy it is 
deactivated (no call processing activity may include the busied object). Warning 
alarms (error type ???) are generated on each busied out port. The command, 
release pri-endpoint, reactivates all ports (B-channels) associated with the 
specified PRI endpoint extension and the switch attempts to negotiate with the 
far-end PRI terminal adapter to reactivate each PRI endpoint port (B-channel).
Port
Port address (cabinet-carrier-slot-circuit)
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains 
station extension
trunk
xxx/yyy
 (where 
xxx
 = trunk group number
and 
yyy
 = member number)
private CO line
P/xxx
 (where 
xxx
 = private CO line group number)
Maintenance Name
Type of busied out maintenance object.
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 busyout port 01C0701 SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 01C0701 ANL-LINE PASS
 Command successfully completed