User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-12busyout packet-control 
8
Feature Interactions
■ In a duplicated system, the packet-control busyout of standby process 
complex is not allowed.
■ When the packet-control in the active control complex is busied out, all 
connectivity across the Packet Bus is severed. Thus, all ISDN-BRI 
point-to-point signaling links that have been established through the 
active packet-control are torn down by the busyout packet-control 
command. The release packet-control command re-establishes all 
Packet Bus connectivity.
Output
The following example shows the output from the busyout packet-control 1A 
command. The responses display on a test-by-test basis with one line of data for 
each test result.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout 
packet-control
location
Location applies to 
duplicated 
configurations only. 
Location represents a 
carrier that contains 
packet-control in the 
system. Valid locations 
= 1A or 1B.
Examples
busyout 
packet-control 1A 
busyout 
packet-control 1B
init
inads
craft
simplex systems 
(optional) = cabinet 
1, carrier A 
duplex systems = 
cabinet 1, carrier of 
choice.
See below
 busyout packet-control 1A SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 1A PKT-CTRL PASS
 Command successfully completed