User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Error Messages 
Page A-51refresh spe-standby 
A
If a cabinet number of "1" or "01" is entered and the carrier specified is "A" or "B" in an 
SPE duplex system, the carrier specified is "A" in a SPE simplex system or if the "A" 
carrier is specified with a cabinet other than "1" or "01, or an SCC carrier location is 
given," the following message will be displayed:
 Cannot recycle control carriers or XE carriers
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
login id’:’command’ has a command conflict 
refresh spe-standby
Help Messages
If the system technician presses HELP after entering "refresh spe-standby," the following 
message will be displayed:
 Entry is not required
Error Messages
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
 ’login id’:’command’ has a command conflict
release access-endpoint
Help Messages
If the user presses HELP after entering "release access-endpoint," the following message 
is displayed:
 Enter assigned extension
Error Messages
If the format for the extension is incorrect, the following error message will be displayed:
 Extension invalid
If the EPN on which the access endpoint resides is not accessible, the following 
message will be displayed:
 EPN is not available