User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-3busyout board 
8
ports do not receive dial-tone. Warning alarms are generated on each busied out 
port in the access endpoint. The release access-endpoint command returns all 
the ports associated with the specified access endpoint to operation.
!
WARNING:
This command is service disrupting and may cause extraneous alarms.
Output
The following example shows the output from the busyout board 1c07 
command, and assumes that board in cabinet 1, carrier c, slot 7 is an analog 
board with three administered ports. The responses display on a test-by-test 
basis with one line of data for each test result.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout board
location
Board address (PCSSpp)
Examples:
busyout board 01c11 
busyout board 02c15
init
inads
craft
none None
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
The name of maintenance object
 busyout board 01C07 SPE A
 COMMAND RESULTS
 Port Maintenance Name Alt. Name Result Error Code
 01C07 ANL-BD PASS
 01C0702 ANL-LINE PASS
 01C0701 ANL-LINE 51001 PASS
 01C0703 ANL-LINE PASS
 Command successfully completed