Maintenance Object Repair Procedures 
Page 10-1560XXX-BD (Common Port Circuit Pack) 
10
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the 
maintenance strategy that is recommended for this error type.
2. Run the busyout board, reset board, and release busy board 
commands,and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there are no 
problems found, replace the circuit pack.
1004 ABORT The port was seized by a valid call during the test. The test has been 
aborted. Use the display port PCSSpp command to determine the station 
extension. Use the status station command to determine the service state 
of the port. If the service state indicates that the port is in use, the port is 
unavailable for certain tests. (Refer to the "Status Commands" section in 
Chapter 8, ‘‘
Maintenance Commands and Trouble-Clearing Aids’’ for a full 
description of all possible states.) You must wait until the port is idle before 
retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is idle, escalate the problem.
1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the 
ringing circuits are in use; the ringing generator is defective; ringing 
generator is not wired correctly.
1. If the test continues to abort, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to RING-GEN Maintenance 
documentation and try to resolve any problem(s). Go to Step 2.
b. If there are no RING-GEN errors, and the test continues to abort, 
issue the test board PCSS command on other TN742, TN769, or 
TN746 Analog circuit packs. If an ABORT with error code 1008 
occurs for this test on other circuit packs as well, the ringing 
generator may be defective or may not be wired properly. Refer to 
RING-GEN Maintenance documentation for details. If an ABORT 
with error code 1008 does NOT occur on the other ports, then all 
four ring generators are in use. Exit from this documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
Table 10-527. TEST #51 Ringing Application Circuit Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page