DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1557XXX-BD (Common Port Circuit Pack) 
10
approximately every 10 minutes. If the hardware problem is resolved, the 
"leaky bucket" strategy should clear the alarm in approximately 30 
minutes. However, if the alarm does NOT clear in 30 minutes, the circuit 
pack should be replaced.
i. This error can be ignored, but look for other errors on this circuit pack.
j. This error is not service-affecting and no action is required.
k. This error indicates that no ringing current is detected. Run Test #51, 
Ringing Application Test, and follow the procedures for Test #51. This 
error is only applicable to Analog Line circuit packs.
l. The hyperactive circuit pack is out-of-service and may exhibit one or more 
of the following symptoms:
1. The common circuit pack level tests such as Test #51 and/or Test 
#220 are aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning with a 
NO-BOARD.
3. A busyout/release of the circuit pack has no affect on test results.
4. A list configuration command shows that the circuit pack and 
ports are properly installed.
If the XXX-BD is not a TN754 Digital Line Circuit Pack (DIG-BD), and if this 
error happens again within 15 minutes, replace the circuit pack. If the 
XXX-BD is a TN754 Digital Line Circuit Pack (DIG-BD), check the alarm 
level. If the alarm level is a WARNING, this indicates that users are 
probably causing the hyperactivity by playing with their digital stations. If 
the circuit pack is really hyperactive, this alarm is upgraded to a MINOR 
alarm within one hour. If the alarm level is a MINOR alarm, replace the 
circuit pack. (Refer to the ‘‘
Handling Control Circuit Packs’’ section in 
Chapter 5, ‘‘
Routine Maintenance Procedures’’.)
m. This error indicates that no neon current is detected. Run Test #220, Neon 
Test, and follow the procedures for Test #220. This error is applicable only 
to TN769 and TN746 Analog Line circuit packs.
n. This error is not service-affecting and no action is required.
o. Error type 3999 indicates that the circuit pack sent a large number of 
control channel messages to the switch within a short period of time. If 
error type 1538 is also present, then the circuit pack was taken 
out-of-service due to hyperactivity. If error type 1538 is not present, then 
the circuit pack has not been taken out-of-service, but it has generated 
50% of the messages necessary to be considered hyperactive. This may 
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.