Maintenance Object Repair Procedures 
Page 10-1556XXX-BD (Common Port Circuit Pack) 
10
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack 
has been removed and/or SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same 
slot as the error indicates) to resolve this error. Or, if the circuit pack is in 
the system and the red LED is on, follow the instructions for "Red (alarm)" 
in the ‘‘
Control and Port Circuit Pack Status LEDs’’ section in Chapter 7, 
‘‘LED Interpretation’’ (See also the ‘‘Handling Control Circuit Packs’’ 
section in Chapter 5, ‘‘
Routine Maintenance Procedures’’)
b. This error indicates the circuit pack has been busied out. Release the 
circuit pack via release board PCSS.
c. The circuit pack has been logically administered but not physically 
installed. The alarm should clear when the circuit pact is installed.
If the circuit pack is already installed:
1. Run test board PCSS long and look at any test failures or error 
codes generated.
2. If the test does not clear error 23, then execute reset board PCSS 
and run the long test again.
3. If the reset/test does not clear error 23, replace the circuit pack. 
d. This error applies only to the Maintenance/Test circuit pack (TN771B or 
TN771C). The error indicates that the hardware associated with the 
Analog Trunk Testing port of the circuit pack failed to initialize. This port is 
not used in G3iV1.1-286 or G3iV2-386. Note, however, that when this error 
occurs, the Maintenance/Test circuit pack may report an invalid vintage. 
Although this error is not service-affecting, the Maintenance/Test circuit 
pack should be replaced.
e. A wrong circuit pack is inserted in the slot where this circuit pack is 
logically administered. To resolve this problem, either remove the wrong 
circuit pack and insert the logically administered circuit pack OR use the 
change circuit-pack command to readminister this slot to match the 
circuit pack inserted.
f. This error applies to the Maintenance/Test circuit pack (TN771D), Tone 
Detector (TN748B, TN748C, or TN748D), and Call Classifier (TN748) 
circuit packs. For the Maintenance/Test circuit pack, the error indicates 
that there is more than one Maintenance/Test circuit pack in the port 
network. For the Tone Detector or Call Classifier packs, the error indicates 
that there are more than 10 circuit packs in the system. Remove the circuit 
pack against which the error is logged.
g. This error indicates transient communication problems with this circuit 
pack. This error is not service-affecting and no action is required.
h. This error, when reported with Aux data in the range of 4352 to 4358, 
indicates that the circuit pack has reported an on-board hardware failure. 
The circuit pack continuously tests the hardware and report the results 