User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1546WAE-PORT (Wideband Access Endpoint Port) 
10
Notes:
a. The wideband access endpoint has been busied out by a busyout 
access-endpoint <extension> command. No calls can be made to this 
extension.
b. The circuit pack has been removed, or it has been insane for more than 11 
minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair 
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair 
procedures.
e. There was a failure of the TN464C UDS1 Interface circuit pack. See 
UDS1-BD Maintenance documentation for details.
f. The Port Audit and Update Test (#36) failed due to an internal system 
error. Enter the status access-endpoint <extension> command and 
verify the status of the port. If the wideband access endpoint is 
out-of-service, enter the release access-endpoint <extension> 
command to put it back to in-service. Retry the test command. If the test 
continues to fail, escalate the problem.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test
, for example, you may also clear errors generated from other tests 
in the testing sequence.
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. (The TN464C UDS1 circuit pack has one 
SCOTCH-NPE chip instead of several NPE chips). The NPE controls port 
connectivity and gain, and it provides conferencing functions on a per-port 
basis. The NPE Crosstalk Test verifies that this port’s NPE channel talks on the 
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Port Audit and Update Test (#36) X X ND