Maintenance Object Repair Procedures 
Page 10-1538VC-LEV (Voice Conditioner DSP Port Level) 
10
Error Log Entries and Test to Clear Values
Notes:
a. The number of VC resources in the system that are in service has fallen 
below the calculated minimum value. If the number of in-service VC ports 
falls below the MMCH port capacity (value entered in the Minimum 
Maintenance Threshold VCs field on the system parameters maintenance 
form), a VEC-LEV error is logged. If this outage continues for 15 minutes a 
MAJOR alarm is raised. To resolve this alarm, correct the out-of-service 
problem by following the procedures below:
1. See “VC-DSPPT” and “VC-BD” and resolve any associated alarms.
2. If a VC-LEV error/alarm exist and none has been raised against 
VC-BD or VC-DSPPT maintenance objects, a VC circuit pack may 
have been removed from service causing the VC-LEV error/alarm. 
To resolve a VC-LEV MAJOR alarm, restore the number of VC ports 
available for service to be equal to or more than the calculated port 
capacity. See “Resolving VC-LEV ERRORS/ALARMS” for details.
System Technician-Demanded Tests: 
Descriptions and Error Code
There are no System Technician-Demanded test for VC-LEV.
Table 10-518. VC-LEV Error Log Entries 
Error 
Type
Aux 
Data Associated Test Alarm Level
On/ Off 
Board Test to Clear Value
1 (a) Any None MAJOR OFF