Maintenance Object Repair Procedures 
Page 10-1524VC-BD 
10
Notes:
a. The circuit pack stopped functioning or it was removed from the system. 
This alarm is logged approximately 11 minutes after the circuit pack is 
removed and/or the SAKI Sanity Test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error 
indicates, if the circuit pack is not already in the system. Or, if the circuit 
pack is in the system and the red LED is on, then follow instructions for 
Red alarms.
!
CAUTION:
If the TN788 Voice Conditioner Circuit Pack (VC-BD) is not Vintage 2 
or later, it must be replaced.
b. This circuit pack is busied out by the busyout board PCSS command.
c. Transient communication problems exist between the switch and this 
circuit pack. Execute the test board PCSS command and refer to the 
repair procedures for the Control Channel Loop Around Test (#52).
d. The circuit pack detected an on-board hardware failure. The reported aux 
data values correspond to the following detected errors:
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the 
appropriate test description and follow the recommended procedures.
1025 (f) 4363 NPE Audit Test (#50)
1281 (g) Any SAKI Sanity Test (#53) MAJ ON
1293 to 
1294 (h)
46088 
to 
46096
SAKI Sanity Test (#53) MIN ON See note (g)
1538 (i) 46082 MIN ON
Error Description
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error 
Table 10-512. VC-BD Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page