Maintenance Object Repair Procedures 
Page 10-1501UDS1-BD (UDS1 Interface Circuit Pack) 
10
1039 ABORT The UDS1 Interface circuit pack is providing timing for the system. 
Executing this test could cause major system disruption. If the UDS1 
Interface circuit pack needs to be tested, set the synchronization reference 
to another DS1 Interface circuit pack or to the Tone-Clock circuit pack via 
the following command sequence: 
1. Issue the disable synchronization-switch command. 
2. Issue the set synchronization PCSS command.
3. Issue the enable synchronization-switch command. Then rerun the 
test. If the test aborts again, a different ABORT error code will be 
generated. Follow the recommended maintenance procedures for that 
error code.
1950 ABORT Another loopback/span test is already executing on the DS1 boardor the 
board is in a network requested loopback mode (Line loopback or Payload 
loopback). The hardware error log will indicate whether a Customer 
Loopback Jack Test, Far CSU Loopback Test, or the One-Way Span Test is 
executing or if the board is in line loopback or payload loopback mode. 
Only one long-duration loopback/span test can be active at a given time. 
Thus, if a loopback/span test is already active, that test must be terminated 
via the 
test ds1-loop PCSS end-loopback/span-test
 command in order to 
execute this test.
1951 ABORT The CSU Repeater Loopback Test could not be executed because the 
120A1 CSU Module was not physically installed. Physically connect the 
120A1 CSU Module to the TN464F board on the back of the port carrier.
Table 10-505. TEST #1211 CSU Repeater Loopback Test — Continued