User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1496UDS1-BD (UDS1 Interface Circuit Pack) 
10
In addition, the DS1 circuit pack hardware applies a DC current while the test is 
running in order to detect any broken wires which may not be detected by the 
loopback pattern itself.
When the test is complete, all trunks or ports on the TN464F UDS1 Interface 
circuit pack are restored to the in-service state after the release board command 
is entered.
Table 10-504. TEST #1210 CSU Equipment Loopback Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error 
1. Retry the 
test ds1-loop PCSS ds1/csu-loopback-tests
 command at 
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT CSU Equipment Loopback Test cannot be executed in the current 
configuration. To run this test, the 
Near-End CSU Type
 field on the DS1 
circuit pack administration form must be set to 
integrated
 and the "Bit Rate" 
field must be set to "1.544" (24-channel operation).
1. Use the change ds1 PCSS command to set the 
Near-End CSU Type
field on the DS1 circuit pack administration form to 
integrated
, and/or 
change the "Bit Rate" field to "1.544" if the board is to be used in 
24-channel configuration. 
2. Retry the 
test ds1-loop PCSS ds1/csu-loopback-tests
 command. 
3. If the test continues to abort, escalate the problem.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been busied out to 
out-of-service. 
1. Enter the busyout board PCSS command to put all trunks or ports of 
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command. 
3. If the test continues to abort, escalate the problem.