User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1490UDS1-BD (UDS1 Interface Circuit Pack) 
10
1 to 17
(cont’d.)
FAIL
(cont’d.)
If the UDS1 connects to a line-side terminating device such as a PRI 
terminal adapter:
1. Retry the command at 1 minute intervals for a maximum of 5 times.
2. Enter the list measurement ds1-log PCSS command to read the error 
seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and line 
coding.
4. Investigate the maintenance status of the line-side terminating device. 
Refer to the ’Line-Side Terminating Device Operating Manual’ for 
information.
5. Contact the vendor of the line-side terminating device to diagnose the 
equipment.
6. Check the physical connection of the UDS1 interface circuit pack to 
the terminating device, and check the premise distribution system (or 
the intra-premise wiring) for physical connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the test.
  PASS No Misframe alarm is detected on the UDS1 Interface circuit pack.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the add ds1 
PCSS command to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 10-501. TEST #145 Misframe Alarm Inquiry Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page