Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a UDS1 Interface circuit 
pack are in error. The Misframe Alarm Inquiry Test queries the total number of 
misframes that have occurred on a DS1 Interface circuit pack since the last 
inquiry.
When the DS1 Interface circuit pack detects a misframe error, it will increase its 
misframe counter by 1. If the counter reaches a specified threshold (i.e.- 17), a 
MISFRAME-COUNT message is automatically sent to the switch maintenance 
software. After the maintenance software receives the MISFRAME-COUNT 
message, the Misframe Alarm Inquiry Test is initiated to collect the misframe 
counts from the UDS1 Interface circuit pack.
When the threshold of misframes is reached, if the UDS1 Interface circuit pack is 
supplying the system synchronization source, then a switching synchronization 
source message is sent to the TDM Bus Clock. See TDM-BUS (TDM Bus) 
Maintenance documentation for details. A Minor alarm against the UDS1 
Interface circuit pack is raised, but all trunks or ports of the UDS1 Interface circuit 
pack remain in the in-service state.