Reliability Systems: A Maintenance Aid 
Page 6-33Blocking Standby SPE Maintenance Activities for System Testing 
6
Maintenance activity is performed automatically on the Standby SPE after the 
SPE Select Switches are returned to their AUTO positions in Step 4. This can be 
verified by issuing the status system command and noting that the Standby SPE 
is labeled as “maint.” The maintenance activity takes from 10 to 30 minutes to 
complete. (The time required for the maintenance activity to complete depends 
upon the number of TN765 Processor Interface circuit packs, the number of 
administered ports on the Processor Interface circuit packs, the number of 
administered data channels on the TN777B Network Control circuit pack, and the 
current load on the system.) The completion of the maintenance activity can be 
verified by issuing the status system command and noting whether the Standby 
SPE is labeled as ”standby.”
Although not recommended at this stage of the procedure, the maintenance 
activity on the Standby SPE can be preempted using the refresh spe-standby 
command. To preempt the maintenance activity, continue issuing the refresh 
spe-standby command followed by status system command until the status 
system form shows that the Standby SPE is labeled ”standby.”
It may be necessary to issue the refresh spe-standby command multiple times 
to preempt all Standby SPE maintenance activity. If the refresh spe-standby 
command successfully completes five times without the Standby SPE becoming 
labeled “standby” on the status system form, wait 20 minutes. This does not 
include cases where the command completes with the G3MT terminal message 
line errors “Refresh not successful; use ‘display errors’ to check for STBY-SPE 
errors” or “Cannot interrupt Standby SPE while entering maintenance mode; 
please try later.”
Issue the refresh spe-standby command once more.