Maintenance Object Repair Procedures 
Page 10-1421TONE-PT (Tone Generator) 
10
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT Could not allocate the necessary system resources to run this test. 
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow normal escalation procedures.
FAIL The Tone Generator could be defective. In a Port Network with more than 
one Tone-Clock circuit pack, the system will attempt to move the tone 
generation function to the alternate one.
1. Test the Tone-Clock circuit pack again via the test tone-clock PC 
command
2. If the test fails again, look at the Hardware Error Log for Tone Detector 
circuit pack errors.
3. If there are Tone Detector circuit pack errors, refer to Tone Detector 
Maintenance documentation (DTMR-PT, GPTD-PT, CLAS-PT, ETR-PT) 
to resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the Tone-Clock 
circuit pack should be replaced. See ‘‘
How to Replace a Tone-Clock 
Circuit Pack’’ in the TONE-BD section.
PASS The tone generation facility is able to put tones out.