Maintenance Object Repair Procedures 
Page 10-1364TIE-DS1 (DS1 Tie Trunk) 
10
FAIL The far-end trunk did not respond to the seizure of the near-end trunk 
within the allowable time period. This test could have associated in-line 
errors in the error log.
1.  1) Enter the list configuration board UUCSS command. If the circuit 
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a 
subsequent failure of test 7 due to a firmware bug. Eventually, the 
board and all of its ports will be taken out of service and extraneous 
on-board alarms will be generated. Replace the circuit pack with a 
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If 
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance 
documentation or to the UDS1-BD (UDS1 trunk circuit pack) 
Maintenance documentation.
4. Retry the test at 1 minute intervals for a maximum of 5 times.
5. If the test continues to fail, escalate the problem.
2000 FAIL Response to the seizure message was not received within the allowable 
time period.
1. Enter the list configuration board UUCSS command. If the circuit 
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a 
subsequent failure of test 7 due to a firmware bug. Eventually, the 
board and all of its ports will be taken out of service and extraneous 
on-board alarms will be generated. Replace the circuit pack with a 
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If 
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance 
documentation or to the UDS1-BD (UDS1 trunk circuit pack) 
Maintenance documentation.
4. Retry the test at 1 minute intervals for a maximum of 5 times.
5. If the test continues to fail, escalate the problem.