Maintenance Object Repair Procedures 
Page 10-1351TIE-DS1 (DS1 Tie Trunk) 
10
d. Error Type 130—This error type indicates that the circuit pack has been 
removed or has been insane for more than 11 minutes. To clear the error, 
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware error 
on the DS1 tie trunk. The trunk cannot communicate with the far end 
because it is unable to interpret digits sent from the far-end switch. The 
Aux Data field indicates the following:
Check with the far-end switch or operating company for proper trunk 
connection.
f. Error Type 513—DS1 Interface circuit pack detects a hardware error on 
the DS1 tie trunk. The trunk is in-service/active and waiting for an 
‘‘on-hook’’ from the far-end switch. No calls can be routed over the trunk 
while it is in this state. Aux Data 57392 indicates no external release on 
PBX disconnect. Check with the far-end switch or operating company for 
proper trunk connection.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware error 
on the DS1 tie trunk. This error usually occurs after one or more 
occurrences of error type 513. The trunk has received the belated 
‘‘on-hook’’ that it has been waiting for from the far-end switch. The trunk is 
restored to in-service/idle and can be used for calls. Aux Data 57393 
indicates delayed external release on PBX disconnect. This error can be 
ignored.
h. Error Type 1793—The DS1 Interface circuit pack is out-of-service. See the 
appropriate DS1-BD/UDS1-BD (DS1/UDS1 Interface Circuit Pack) 
Maintenance documentation for details.
i. Error Type 2305—Reorder message. The trunk could not be seized. This 
error will cause the Trunk Seizure Test (#136) to run and is only 
considered a problem if the Seizure Test fails (in which case Error Type 
1025 will also show up). In this case, the trunk may be put in 
‘‘Ready-for-Service’’ state (shown as ‘‘disconnected’’ by the status 
command), which allows only incoming calls. Run the Trunk Seizure Test 
(#136) and follow its outlined procedures.
j. Error Type 2562—Retry Failure error. This error is logged only. It is not a 
hardware failure and hence does not start any testing or generate any 
alarms. This error comes from call processing and is generated when a 
second attempt (retry) to seize an outgoing trunk fails.
k. Error Type 2817—Glare error. This error is logged only. It is not a 
hardware failure and hence does not start any testing or generate any 
alarms. This error is the result of a simultaneous seizure of a two-way trunk 
from both the near-end and the far-end. Attempt to place the call again. If 
the error persists, execute the DS1 Tie Trunk Seizure Test (#136) and 
follow its outlined procedures.
57473 The rotary dial rate is below 8 pulses per second.
57474 The rotary dial rate is above 12 pulses per second.