User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1350TIE-DS1 (DS1 Tie Trunk) 
10
a. Error Type 1—The DS1 Interface circuit pack detects a hardware error on 
the DS1 tie trunk. This error can be caused by incompatible translations. 
Make sure the parameters administered on the DS1 circuit pack form 
match those administered on the far-end switch. See 
DEFINITY 
Communications System Generic 3 V2 Implementation,
 555-230-653, and 
DEFINITY Communications System Generic 2.2 and Generic 3 V2 
DS1/CEPT/ISDN-PRI Reference
, 555-025-107, for details.
The Aux Data field indicates the following hardware error types:
If all administration errors between the switch and the far-end match, and 
these errors continue to recur, follow normal escalation procedures.
b. Error Type 15—This is a software audit error that does not indicate any 
hardware malfunction. Run Short Test Sequence and investigate 
associated errors (if any).
c. Error Type 18—The DS1 tie trunk has been busied out by a busyout trunk 
grp/mbr command. No calls can be made on this trunk except for the 
Facility Access Test Call. Facility Access Test Calls are described in 
DEFINITY Communications System Generic 3 Feature Description,
555-230-204.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator 
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group 
are out of service, then the alarm will be upgraded to a MAJOR alarm.
3. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set 
options command. If the MINOR alarm is not downgraded by the set options values, the MINOR 
alarm is upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
2562(j) 16665
2817(k) 52992
3840 (j) Any Port Audit and 
Update (Test #36)
57476 On-hook before wink
57477 On-hook before ready to receive digits
57485 Wink too short for valid signal
57487 The timer expired while waiting for an off-hook 
signal from the far end as a response at end of 
digits dialing. Check the far-end switch for related 
problems.
DS1 Tie Trunk Maintenance Error Log Entries
Continued on next page