User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1310TBRI-TRK (TN2185 ISDN Trunk-Side BRI) 
10
2214 ABORT Call terminated by unexpected disconnect.
1. Wait one minute and then try again.
2215 
2216 
2217 
2218 
2219
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2220 ABORT Call terminated prematurely.
1. Wait one minute and try again.
2221 
2222 
2223 
2224 
2225 
2226
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2227 ABORT Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
2042 FAIL This is the main purpose of the test. The comparison of the data sent 
with the data received indicates a loss of integrity on the communications 
path.
1. The trunk should be taken out-of-service and the quality of the ISDN 
Trunk-side BRI line should be investigated. The investigation should 
include an in-depth analysis of the facility including the transmission 
facility and any external equipment such as DACs, CSUs, etc.
PASS The call worked. A test pattern was sent and received properly; the 
communications path is OK if the synchronous test call command was 
issued. An in-depth analysis of the ISDN Trunk-side BRI trunk facility 
including the transmission facility and any external equipment such as 
DACs, CSUs, and others should take place if the bit and block error rates 
are not acceptable.
Table 10-453. TEST #258 ISDN TEST Call — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page