Page 10-1292TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
10
Table 10-445. TEST #619 BRI Port Local TDM Loop Around 
Error 
Code
Test 
Result Description/ Recommendation
1000 ABORT The system resources required to run this test are not available. The port 
may be busy with a valid call. Use the display port PCSSpp command to 
determine the trunk group/member number of the port. Use the status 
bri-port PCSSpp command to determine the service state of the port. If the 
service state indicates that the port is in use, then the port is unavailable for 
certain tests. Wait until the port is idle before retesting.
1. If the port is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS to diagnose any active TDM Bus 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log and if present, refer to 
TTR-LEV.
2. Look for TONE-PT errors in the Error Log and if present, refer to 
TONE-PT.
3. If neither condition exists, retry the test at 1-minute intervals a 
maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the status trunk 
command for the trunks associated with this port and determine when the 
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
1005 ABORT This test is not valid for this type of translation. Ports administered as ASAI 
or ADJK cannot run this test because the B channels associated with the 
port are not used by ASAI or AT&T Adjunct Links. This is a normal 
condition.
2000 ABORT Response to the test was not received from the BRI-LINE circuit pack 
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack with 
the busyout board PCSS and the reset board PCSS commands if the 
other ports on the board are not in use.
2. If this result occurs again, replace the circuit pack.
Continued on next page