Maintenance Object Repair Procedures 
Page 10-1276TBRI-BD (TN2185 ISDN Trunk-Side BRI) 
10
Notes:
a. The circuit pack stopped functioning or is physically removed from the 
system.
NOTE:
This alarm logs approximately 11 minutes after removing the circuit 
pack and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot 
as the error indicates. See note (g).
b. Transient communication problems between the switch and this circuit 
pack. Execute the test board PCSS command and refer to the repair 
procedures for the Control Channel Loop Around Test (#52).
c. On-board hardware failure. Aux data values correspond to the following 
detected errors:
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
1795 (i) 46085 MINOR ON
2305 (j) 46104 None ON
2306 (i) 46081 None ON
3330 (j) 46083 MINOR OFF
3586 (k) MINOR OFF
3840(l) 4096
to
4101
3842 (m) 46095
3843 (n) 46097
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error
Table 10-438. TBRI-BD Error Log Entries  — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page