Maintenance Object Repair Procedures 
Page 10-1272TAPE-DAT (Tape Consistency) 
10
84 FAIL The update files, load vintages, and announcements are different in both 
SPEs. The Standby SPE has the most current update file and 
announcements.
85 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current translations, 
and the Standby SPE has the most current update file and announcements.
86 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Standby SPE has the most current update file, 
translations, and announcements.
1. Follow the procedures for Error Code #4 to get the correct load 
vintage. After running the test tape long command, check for Error 
Code #32 or #64. Follow the recovery procedure under the applicable 
error code. 
PASS The load vintages, translations, announcements, and update files are the 
same.
Table 10-437. TEST #421 Tape Data Consistency Check Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page