Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1235TAPE (Tape Unit) [G3iV1.1-286] 
10
The auxiliary data field indicates the file on the tape in which the error was 
detected. Refer to Table C for a list of possible auxiliary data field values 
and the corresponding tape file.
Since this error may be the result of a problem with either the tape or the 
tape drive unit, the tape cartridge should be changed first. If the problem 
persists, the tape unit should be changed. When this error is first 
detected, follow "Error Type #1793 - Repair Procedure."
Error Type #1793 - Repair Procedure: 
1. Replace the tape cartridge in the tape unit on which the error 
occurred with a new tape cartridge.
2. [G1.2, G3iV1.1-286] Issue the test tape [a/b] long clear command 
for the associated tape drive unit.
[G1.1] Issue the test tape [a/b] long repeat 3 command for the 
associated tape drive unit. If the system release is earlier than 
G1.1, refer to Note (o) also.
3. If all tests pass, assume that the problem has been resolved.
If some tests fail, resolve those errors and repeat Step #2.
4. If translations have not already been saved onto the new tape, 
issue the save translations command.
5. If the system contains recorded announcements, issue the save 
announcements command.
If this error reappears and becomes a chronic problem, the fault may be 
with the tape drive unit, and it could be intermittent in nature. In this case, 
replace the tape drive unit with a new tape drive unit and repeat "Error 
Type #1793 - Repair Procedure." Refer to Step 5 of the ‘‘
Tape 
Maintenance and Repair Procedures’’ section for directions on how to 
replace the tape drive unit.
e. Error Type #1828 is reported under the following conditions;
■ [G3iV1, EDI 7.0 and earlier] This error is never reported. 
■ [G3iV1, EDI 6.0 and earlier] Whenever Test #692 (Tape Block Error 
Test) fails due to an uncorrectable tape block error.
■ [G1.1] Whenever any maintenance test fails due to an 
uncorrectable tape block error.
To clear Error Type #1828, follow the procedures given in the footnotes for 
Error Type #1793.
f. Error Type #2049 is reported under the following conditions;
■ [G3iV1 EDI 7.0 and later] This error is never reported. 
■ [G1.1, G3iV1 EDI 6.0 and earlier] Error Type #2049 is reported 
whenever the software detects a correctable tape block error 
during a read or write operation on the tape.