User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1226SYS-PRNT (System Printer) 
10
Make sure that the SYS-PRNT output device is 
on-line
 and 
ready-for-service. Check the physical connectivity between the Data 
Module and the SYS-PRNT output device or between the EIA port on the 
backplane of the switch and the SYS-PRNT output device.
6. Verify that there are less than three active logins to the system. If this 
condition exists, a login session must be terminated before the System 
Printer Link can be established.
NOTE:
It is recommended that the System Printer Link be busied out before 
executing maintenance tests over objects which compose the 
System Printer Link. If the System Printer Link is busied out, then all 
System Printer Link maintenance actions are deactivated.
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the System Printer Link.
b. A failure was encountered while attempting to set up the System Printer 
Link. This attempt could have been initiated by either the Report 
Scheduler software or link maintenance [automatic link retry or the as the 
result of a Link Retry Test (#215) request]. The Aux Data field contains the 
following diagnostic information to aid in the correction of the failure:
1. unavailability of system resources (too many active logins to the 
system).
2. no data channels (DATA-CHLs) available on the Network Control 
circuit pack (DATA-BD).
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the 
set options command.
Table 10-422. SYS-PRNT Maintenance Error Log Entries
Error 
Type
Aux 
Data Associated Test Alarm Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test sp-link
18 (a) 0 busyout sp-link WARNING OFF release sp-link
257 (b) 1 to 6 Link Retry Test 
(#215)
MINOR/ 
WARNING
2
OFF test sp-link l
513 (c) 0 None MINOR OFF test sp-link