Page 10-1222SYNC (Synchronization) 
10
■ If the system synchronization reference is a DS1 interface 
circuit pack and the master Tone-Clock circuit pack fails 
TDM Bus Clock Test #150, the primary or secondary (if 
administered) synchronization references are not providing 
valid timing signals for the system. Check the system 
synchronization references administered, and follow the 
steps outlined in note (a) if the primary synchronization 
reference is providing timing for the system or note (c) if the 
secondary synchronization reference is providing timing for 
the system.
■ If the slave Tone-Clock circuit pack fails the TDM Bus Clock 
Test #150 but the master Tone-Clock does not fail this test, 
the master Tone-Clock circuit pack must be replaced. Follow 
the Tone-Clock replacement steps listed in the “TDM-CLK”.
If SLIP errors remain follow SLIP ANALYSIS.
5. Standard system:—Error 2305:
■ Replace the Expansion Interface circuit pack in this port 
network and the Expansion Interface circuit pack in the PPN 
that is connected to this port network.
■ If the problem persists, replace the Tone-Clock circuit pack 
in the slave port network. Follow the steps listed in 
“TDM-CLK” to replace the Tone-Clock circuit pack.
i. Noise on the DS1 line can cause transient alarms on synchronization. 
Therefore, when a synchronization problem occurs causing error types 1, 
257, or 513, a WARNING alarm is first raised for 15 to 20 minutes before 
the alarm is upgraded to a MAJOR or MINOR alarm.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Test Synchronization Test,
 for example, you may 
also clear errors generated from other tests in the testing sequence.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
Test Synchronization Test (#417) X X ND