Maintenance Object Repair Procedures 
Page 10-1211SW-CTL (Switch Control) 
10
2013 
32511
ABORT Could not allocate the system resources to run for this test.
2012 
32513 
32514
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to “Standby SPE” for a description of these error codes.
32515 FAIL This failure indicates that communications with the Maintenance circuit 
pack in the EPN is probably not possible. The EPN management terminal 
may not be usable.
1. Run the Long Test Sequence several times to make sure the error is 
occurring consistently. Remember the Long Test Sequence is 
destructive. Placing and receiving calls is affected for several 
seconds.
2. Replace the Netcon circuit pack.
3. The procedure for replacing the Netcon circuit pack is described in 
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’. The procedure for 
doing the same in systems without High or Critical Reliability is 
described in Chapter 5, ‘‘
Routine Maintenance Procedures’’.
PASS The EPN Maintenance circuit pack interface between the processor and the 
Switch Control is working correctly.
Table 10-419. TEST #325 Switch Control Destructive EPN 
Maintenance Board Interface Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page