Table 10-417. TEST #95 Time of Day Clock Test 
Error 
Code
Test 
Result Description/ Recommendation
1000 ABORT The test was interrupted by a higher priority task.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
2. If the test aborts five times, wait until the system is less heavily used and 
rerun the test at that time.
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to STBY-SPE for a description of these error codes.
2012 ABORT Internal system error
2013 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2001 FAIL The Time of Day clock could not be read.
1. Run the set time command and set the time to the current time.
2. Run the Short Test Sequence several times to determine if setting the 
time corrected the error. Proceed to Step 3 if the error is still occurring.
3. Replace the Netcon circuit pack at the customer’s convenience 
(Standard system) or right away (High or Critical Reliability system).
other FAIL The accuracy of Time of Day clock is not within limits. 
1. Run the Short Test Sequence several times to make sure the error is 
occurring consistently.
2. Replace the Network Control (DATA-BD) circuit pack at the customer’s 
convenience (unduplicated system) or right away (High or Critical 
Reliability system).
3. The procedure for replacing the Network Control (DATA-BD) circuit 
pack is described in Chapter 6, ‘‘
Reliability Systems: A Maintenance 
Aid’’. The procedure for doing the same in systems without High or 
Critical Reliability is described in Chapter 5, ‘‘
Routine Maintenance 
Procedures’’.
PASS The Time of Day clock on the Switch Control circuit pack is operating 
correctly.
Continued on next page