Maintenance Object Repair Procedures 
Page 10-1195STRAT-3 (Stratum 3 Clock)] 
10
16 FAIL All power supplies failed.
1. Replace the failed power supplies.
2. If battery backup for the Stratum 3 clock is not supplied or if the 
battery backup holdover time has been exceeded, the system 
references the local oscillator on the Active TN780 Tone-Clock 
circuit pack until software detects one or both power supplies 
has(have) been restored (approximately 40 minutes). To speed 
up this restoration, issue the test synchronization r 4 
command. All tests should pass. If any repetitions should fail, 
follow the procedures for those failures. If the problem persists 
after you have performed this procedure three times, follow 
normal escalation procedures.
32 FAIL All clock unit(s) failed.
1. Look at the Stratum 3 cabinet for red LEDs on circuit cards 
marked "ST3." Replace the card(s).
2. Determine if the alarm still exists by issuing the test 
synchronization r 4 command to clear the alarm. If any test 
repetitions fail, follow the procedure for those failures. If the 
problem persists after you have performed this procedure three 
times, follow normal escalation procedures.
2101 FAIL The TN780 Tone-Clock circuit pack detects loss of signal. Refer to 
Note (b) of the STRAT-3 Hardware Error Log Entries table in the 
STRAT-3 (Stratum 3 Clock) Maintenance documentation for 
replacement procedures.
PASS The Stratum 3 clock has reported that it has no alarm conditions. If 
synchronization problems have been reported, look for SYNC 
errors and refer to SYNC (Synchronization) Maintenance 
documentation for recommended strategy for those errors.
Table 10-412. TEST #649 Stratum 3 Clock Alarm Query — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page