User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1182STBY-SPE (Standby SPE) 
10
2051 ABORT When attempting to refresh Standby SPE memory from Active SPE memory, 
the Active SPE could not determine the status of one of the Duplication 
Interface circuit packs, or it determined that one of the Duplication Interface 
circuit packs was defective.
1. Check for carrier A Duplication Interface circuit pack errors and alarms. 
Refer to DUPINT (Duplication Interface Circuit Pack) Maintenance 
documentation and follow the prescribed procedures.
2. Check for carrier B Duplication Interface circuit pack errors and alarms. 
Refer to DUPINT (Duplication Interface Circuit Pack) Maintenance and 
follow the prescribed procedures.
3. Check the Inter-Carrier Cable to see if the cable is loose or disconnected. 
If so, follow the repair procedures for reconnecting the Inter-Carrier Cable 
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’.
4. If all problems found in Steps 1, 2, and 3 have now been repaired, 
proceed with Step 8. If no problems were found in Steps 1, 2, and 3, 
proceed with Step 5.
5. Issue the display errors command and check to see if Error Type 80 is 
logged against STBY-SPE. If so, the problem is the carrier A Duplication 
Interface circuit pack. Replace the carrier A Duplication Interface circuit 
pack as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ 
and proceed with Steps 8, 9, and 10.
6. Issue the display errors command and check to see if Error Type 82 is 
logged against STBY-SPE. If so, the problem is the carrier B Duplication 
Interface circuit pack. Replace the carrier B Duplication Interface circuit 
pack as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ 
and proceed with Steps 8, 9, and 10.
7. If Error Type 80 or 82 is not logged, escalate the problem.
2051
(cont’d.)
ABORT 8. Issue the refresh spe-standby command to put the Standby SPE in 
Standby Mode. This command may have to be issued multiple times. If the 
refresh spe-standby command successfully completes five times without 
the Standby SPE becoming labeled "standby" on the status system form, 
wait 20 minutes. This does not include cases where the command 
completes with the terminal message line errors "Refresh not successful; 
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt 
Standby SPE while entering maintenance mode; please try later." Issue the 
refresh spe-standby command once more. 
9. Repeat the test.
10. Issue the test spe-standby long command to thoroughly test all Standby 
SPE components.
Table 10-410. Test Result Error Codes Associated with the Standby SPE — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page