User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1170STBY-SPE (Standby SPE) 
10
check for STBY-SPE errors" or "Cannot interrupt Standby SPE while 
entering maintenance mode; please try later." Issue the refresh 
spe-standby command once more. If the Standby SPE is not 
labeled "standby" on the status system form after this attempt, use 
the busyout spe-standby and release spe-standby command to 
put the standby into standby mode.
2. Repeat the command.
3. Issue the test spe-standby long command.
■ Unable to interchange because the active SPE is locked active 
An SPE interchange cannot be performed when the active SPE is locked 
via the SPE select switches. Move the select switches back to the auto 
position and retry the reset system interchange command.
■ Unable to interchange because the standby SPE is busied out 
An SPE interchange can not be performed when the standby SPE is 
busied out. Release the standby SPE by entering the release 
spe-standby command and retry the command.
■ Unable to interchange due to alarms on the standby SPE; Use the 
‘health-override’ option 
When components in the standby SPE complex are alarmed, and if these 
Standby alarms are more severe than the alarms in the active SPE 
complex, the reset system-interchange command returns this message. 
Using the reset system-interchange health-override command forces 
the interchange. See the Reset System command page for more details.