Page 10-1159STBY-SPE (Standby SPE) 
10
r. Error Type 804 is logged when the upgrade software command failed 
due to a loss of communication with the Standby SPE during the reboot 
immediately following a successful software upgrade. This implies that the 
communication path between the Active SPE and the Standby SPE may 
not be functional.
Issue the test duplication-interface a and the test duplication-interface 
b commands. If the tests pass, re-execute the upgrade software 
command.
s. Error Type 805 is logged when the upgrade software command failed 
due to the failure to insert the software card-mem in the Active SPE in time.
The software card-mem should be inserted into the Active SPE at the 
appropriate time so as to allow the upgrade software command to be 
re-executed.
t. Error Type 806 is logged when the upgrade software command failed 
due to a bad flash checksum on the new Standby SPE after an upgrade of 
the old Standby SPE and SPE-Interchange. This implies that the on-board 
flash memory may not be functional. The behavior of the Standby SPE may 
unpredictable.
The upgrade software command should be re-executed. If the command 
fails again, the Standby SPE Processor circuit pack should be replaced.
u. Error Type 807 is logged when the upgrade software command failed 
due to the failure to insert the translation card-mem into the new Standby 
SPE after an upgrade of the old standby SPE and SPE-Interchange.
The translation card-mem should be inserted into the Standby SPE.
v. Error Type 808 is logged when the upgrade software command failed 
due to the loss of communication with the new Standby SPE during an 
upgrade following the upgrade of the old standby SPE and 
SPE-Interchange. This implies that the programming of the Standby SPE 
never completed.
Use the "Special Upgrade Procedure" to re-execute an upgrade on the 
Standby SPE only. If the upgrade fails again, the Standby SPE Processor 
circuit pack should be replaced.
w. Error Type 809 is logged when the upgrade software command failed 
due to the failure to perform an SPE-Interchange immediately after the 
successful upgrade of the Standby SPE. This implies possible problems 
with the Dupint circuit packs.
Issue the test duplication-interface a and test duplication-interface b 
commands. If the tests pass, re-execute the upgrade software 
command.
x. Error Type 810 is logged when the upgrade software command failed 
due to a bad checksum on the software card-mem during the upgrade of 
the new Standby SPE following the successful upgrade of the old Standby 
SPE and of SPE-Interchange.