Page 10-1153STBY-SPE (Standby SPE) 
10
NOTE:
When more than one of the above error types exists at the same time, the 
alarm against the Standby SPE is cleared only when (1) any problems 
described by the Aux Data values for Error Types 1 and 257 are resolved 
and (2) all problems described in (b) through (o) are resolved.
Notes:
a. Aux Data value 0 is equivalent to Aux Data value 2017. All Aux Data values 
listed for Error Type 1 are described in "System Technician-Demanded 
Tests: Test Result Error Codes". These values are shared between 
Standby SPE maintenance activity results and the test results for the 
System Technician commands on Standby SPE components because the 
values represent the common set of problems that can be encountered 
when attempting to conduct any form of maintenance activity on the 
Standby SPE.
b. Error Type 58 is logged when the Duplication Interface circuit pack in the 
A carrier reports that the Standby SPE has gone into Down Mode. This 
implies an inability to communicate with the Standby SPE.
The ability to communicate with the Standby SPE should be checked by 
issuing the test processor a | b short command, where "a | b" indicates 
the carrier that contains the Standby SPE. If all of the tests execute such 
that no test returns an Aux Data value of 2014, 2015, 2016, 2017, 2022, 
2024, or 2025, the Standby SPE was successfully put into Maintenance 
Mode. This indicates that the communication path between the Active SPE 
and the Standby SPE may be functional. However, to restore the 
1. Run the short test sequence first. If all the tests pass, run the long test sequence. Refer to the 
appropriate test description and follow the recommended procedures.
812 (y) any SPE interchanged 
forced with 
health-override 
option:
WARNING OFF See note (y).
822(z) any A non-hot 
interchange to the 
standby SPE 
occurred.
See note (z).
826 (aa) any Standby software 
mismatch
MAJOR ON upgrade software
Table 10-409. Standby SPE Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off
 Board Test to Clear Value
Continued on next page