User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1146SPE-SELEC (SPE Select Switch) 
10
Table 10-408. TEST #278 SPE Select Query Test 
Error 
Code
Test 
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL The switch currently selects SPE-A active.
2 FAIL The switch currently selects SPE-B active.
1. Move the switch to the AUTO position.
2. Rerun the test. 
3 FAIL The Duplication Interface circuit pack is not present or not functioning.
1. Resolve all alarms logged against the Duplication Interface circuit pack 
(DUPINT).
2. Rerun the test.
PASS The Duplication Interface circuit pack has reported that the SPE Select Switch 
is in the AUTO position.
1. If a visual inspection shows the SPE Select Switch is not in the AUTO 
position, then resolve all alarms logged against Duplication Interface 
circuit pack (DUPINT).
2. Repeat the test.
3. If Duplication Interface circuit pack B is being tested and a visual 
inspection shows that the switch is not in the normal position, Duplication 
Interface circuit pack A may be incorrectly reporting the state of 
SPE-Select Switch B. Replace Duplication Interface circuit pack A, and 
rerun the test.
Continued on next page