User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1145SPE-SELEC (SPE Select Switch) 
10
Notes:
a. Refer to the DUPINT (Duplication Interface Circuit Pack) Maintenance 
documentation for description of this test.
b. Refer to the SHDW-CIR (Common Shadow Circuit) Maintenance 
documentation for description of this test.
SPE Select Query Test (#278)
This test queries the Duplication Interface circuit pack for the state of SPE Select 
Switch. The test passes if the switch is in the AUTO position. The test fails if the 
switch is not in the AUTO position or if the Duplication Interface circuit pack is not 
present.
1. D = Destructive; ND = Nondestructive
Duplication Interface Circuit Pack Manager I Loop Back Test (#274) 
(a)
XXND
Inter-Duplication Interface Circuit Pack Loop Back Test (#280) X X ND
Duplication Interface Circuit Pack Background Test Query Test 
(#271) (a)
XXND
Duplication Interface Circuit Pack Invalid Message Query Test 
(#272) (a)
XXND
Common Shadow Circuit M-BUS Time-out Query Test (#285) (b) X ND
Common Shadow Circuit Loop Back Test (#283) (b) X X ND
Common Shadow Circuit Address Decoder Test (#284) (b) X X ND
SPE Select Switch Query Test (#278) X X ND
Order of Investigation
 Long Test 
Sequence
Long Test 
Sequence D/ND
1