User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1105S-SYN-PT (Speech Synthesis Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has 
occurred. Refer to Test #168 for repair procedures.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Speech Synthesis Port Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1(a) 17672 None
18 0 busyout port PCSSpp WARNING OFF release port PCsspp
130(b) None WARNING ON test port PCSSpp sh
257 Speech Synthesis 
PSS Handshake Test 
(#168)
MAJOR ON test port PCSSpp sh r 2
513 17922 Speech Synthesis 
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
769 17664 Speech Synthesis 
DTMF Receiver 
Inquiry Test (#164)
MINOR ON test port PCSSpp sh r 2
1025 17670 Speech Synthesis 
SSD Inquiry Test 
(#167)
MINOR ON test port PCSSpp sh r 2
1281 Speech Synthesis 
DSP Tone Test (#165)
MINOR ON test port PCSSpp sh r 2
1537 Speech Synthesis 
Memory Test (#166)
MINOR ON test port PCSSpp sh r 2
1793 Speech Synthesis 
DTMF Receiver Test 
(#163)
MINOR ON test port PCSSpp l r 2
2049(c) Conference Circuit 
Test (#7)
MINOR ON test port PCSSpp l r 2
2305 NPE Crosstalk Test 
(#6)
MINOR ON test port PCSSpp l r 2
3840(d) Any None